{"product_id":"lyn034160200","title":"Lynx Smart BMS 500 M8","description":"\u003cp style=\"margin-right: 0px; margin-bottom: 1.4em; margin-left: 0px; caret-color: rgb(85, 85, 85);\"\u003e Het Lynx Smart BMS is een specifiek Battery Management System voor Victron Lithium Battery Smart accu's. Er zijn meerdere BMS'en beschikbaar voor onze Lithium Battery Smart serie en het Lynx Smart heeft de meeste functies en volledige opties. \u003cspan style=\"font-family: Aptos, sans-serif; font-size: 11pt;\"\u003eHet is beschikbaar in twee versies: 500 A en 1000 A (beide met M10 verdeelrailaansluitingen).\u003c\/span\u003e\u003c\/p\u003e\u003cp style=\"margin-right: 0px; margin-bottom: 1.4em; margin-left: 0px;\"\u003e\u003cspan style=\"caret-color: rgb(85, 85, 85);\"\u003e De belangrijkste kenmerken zijn:\u003c\/span\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli style=\"margin-right: 0px; margin-bottom: 1.4em; margin-left: 0px;\"\u003e\n\u003cspan style=\"caret-color: rgb(85, 85, 85);\"\u003e Ingebouwde 500 A of 1000 A magneetschakelaar gebruikt als een terugval-veiligheids \u003c\/span\u003emechanisme en ook geschikt als op afstand bestuurbare hoofd-systeemschakelaar.\u003c\/li\u003e\n\u003cli style=\"margin-right: 0px; margin-bottom: 1.4em; margin-left: 0px; caret-color: rgb(85, 85, 85);\"\u003e Accubewaker, laadstatus en meer gegevens worden weergegeven.\u003c\/li\u003e\n\u003cli style=\"margin-right: 0px; margin-bottom: 1.4em; margin-left: 0px; caret-color: rgb(85, 85, 85);\"\u003e Vooralarmsignaal: een waarschuwing geven voordat het systeem uitschakelt vanwege -bijvoorbeeld- een lage celspanning.\u003c\/li\u003e\n\u003cli style=\"margin-right: 0px; margin-bottom: 1.4em; margin-left: 0px; caret-color: rgb(85, 85, 85);\"\u003e Bluetooth voor gebruik met onze \u003ca href=\"https:\/\/www.victronenergy.nl\/panel-systems-remote-monitoring\/victronconnect\" target=\"_blank\" style=\"background-color: rgb(255, 255, 255);\"\u003eVictronConnect-app,\u003c\/a\u003e voor instellen en bewaking, inclusief \u003ca href=\"https:\/\/www.victronenergy.nl\/media\/pg\/VictronConnect_Manual\/nl\/stored-trends---instant-readout.html#UUID-a249901a-7ebe-9a66-3146-b9f5bb5c77af\" target=\"_blank\"\u003eInstant Readout\u003c\/a\u003e (Directe uitlezing) - De belangrijkste gegevens van het BMS in één oogopslag \u003c\/li\u003e\n\u003cli style=\"margin-right: 0px; margin-bottom: 1.4em; margin-left: 0px; caret-color: rgb(85, 85, 85);\"\u003e Lokale en remote bewaking met een Victron GX-apparaat, bijvoorbeeld de \u003ca href=\"https:\/\/www.victronenergy.nl\/panel-systems-remote-monitoring\/cerbo-gx\" target=\"_blank\" style=\"background-color: rgb(255, 255, 255);\"\u003eCerbo GX\u003c\/a\u003e of \u003ca href=\"https:\/\/www.victronenergy.nl\/panel-systems-remote-monitoring\/ekrano-gx\" target=\"_blank\"\u003eEkrano GX\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"margin-right: 0px; margin-bottom: 1.4em; margin-left: 0px; caret-color: rgb(85, 85, 85);\"\u003e Het Lynx Smart BMS maakt deel uit van het modulair Lynx DC Distribution system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eSpecificaties\u003c\/h3\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:14px;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"text-align:left;padding:10px;border-bottom:1px solid rgba(0,0,0,0.15);\"\u003eKenmerk\u003c\/th\u003e\n\u003cth style=\"text-align:left;padding:10px;border-bottom:1px solid rgba(0,0,0,0.15);\"\u003eWaarde\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eallowChargreCurrentRating\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e0.5A at 60VDC, protected by resettable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eallowDischargreCurrentRating1\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e0.5A at 60VDC, protected by resettable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eauxCurrentRating\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e1.1 A continuous, protected by resettable fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003ebatteryCommunicationTerminals\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eTerminals with M8 circular connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003ebusbarConnections\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eM8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003ebusbarDimensions\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e8mm x 30mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003ebusbarMaterial\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003ecolour\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eBlue (RAL 5012)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003ecurrentRating\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e500 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003ecurrentRatingpeak\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e600 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003edataConnection\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003edepth\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eems\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eEN-IEC 61000-6-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003efuseConnections\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003efuseDummy\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eheight\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e190 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eioConnection\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eRemovable multi-connector with screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003elynxDistributorFuseMonitoring\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eRJ10 (RJ10 cables ship with each Lynx Distributor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003ematerial\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003emaxHumidity\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e95 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003emaxInputVoltage\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e75 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eoperatingTempRange\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003epowerConnectionDistributor\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003epowerConsumption\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003epowerConsumptionOff\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e0.3mA for all system voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003epowerConsumptionOn\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eApproximately 2.6W (217mA at 12V) depending on the state of the relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003epowerConsumptionStandby\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eApproximately 0.6W (50mA at 12V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eprechargeLoadResistance\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e10? and above for 12V systems 20? and above for 24V and 48V systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eprogrammableRelay\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eSPDT - 2 A at 60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eprotectionCategory\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eIP22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eqms\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eNEN-EN-ISO 9001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003erelayConnection\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003ereversePolarityProtection\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003esafety\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eEN-IEC 63000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003estorageTempRange\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003esystemVoltages\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e12V or 24V or 48V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003etemperatureSensorConnection\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eveCan\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eRJ45 (Two RJ45 terminators included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003evoltageRange\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e[9, 60] V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003eweight\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e1.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003ewidth\u003c\/td\u003e\n\u003ctd style=\"vertical-align:top;padding:10px;border-bottom:1px solid rgba(0,0,0,0.08);\"\u003e180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eDownloads\u003c\/h3\u003e\n\u003ch4 style=\"margin:14px 0 8px 0;\"\u003eDatasheet\u003c\/h4\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;\"\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Datasheet-BMS-overview-NL.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ BMS Overview\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Datasheet-Lynx-Smart-BMS-NL.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"margin:14px 0 8px 0;\"\u003eEnclosure dimension\u003c\/h4\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;\"\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Smart-BMS-500.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Smart-BMS-500-%283D%29.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500 (3D)\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Smart-BMS-500-%28stp%29.STEP\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500 (stp)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"margin:14px 0 8px 0;\"\u003eHigh quality photo\u003c\/h4\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;\"\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Smart-BMS-%28top%29.png\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500 (M10) (top)\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx%20Smart%20BMS%20%28front%29.png\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500 (M10) (front)\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Smart-BMS-%28top-with-connector%29.png\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500 (M10) (top with connector)\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Smart-BMS-%28front-angle%29.png\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500 (M10) (front angle)\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Smart-BMS-%28right%29.png\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500 (M10) (right)\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Smart-BMS-%28left%29.png\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500 (M10) (left)\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Smart-BMS-%28front-with-connector%29.png\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500 (M10) (front with connector)\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Lynx-Smart-BMS-%28top-with-accessories%29.png\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Lynx Smart BMS 500 (M10) (top with accessories)\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"margin:14px 0 8px 0;\"\u003ePromo video\u003c\/h4\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;\"\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Promo%20videos\/Product%20video%27s\/VictronConnect\/16x9\/NL_VictronConnect.mp4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ VictronConnect\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Promo%20videos\/Ad%20videos\/Brand%20video\/16x9\/NL_Brand%20video.mp4\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Brand video\u003c\/a\u003e\n\u003c\/div\u003e\n\u003ch4 style=\"margin:14px 0 8px 0;\"\u003eSystem schematic\u003c\/h4\u003e\n\u003cdiv style=\"display:flex;flex-wrap:wrap;gap:10px;\"\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Quattro-5KW-230VAC-24VDC-600-800Ah-Li-Lynx-Smart-BMS-%26-distributors-Cerbo-GX-touch-generator-MPPT-Orion-Tr-Smarts.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Quattro 5kW 230VAC 24VDC 600-800Ah Li Lynx Smart BMS \u0026amp; distributors Cerbo GX touch generator MPPT Orion-Tr Smart\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Manual-%26-Drawing-Catamaran-setup-Quattro-5kVA-230VAC-24V-Extra-Alternators-%26-WS500.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Manual \u0026amp; Drawing Catamaran setup Quattro 5kVA 230VAC 24V Extra Alternators \u0026amp; WS500\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Manual-%26-Drawing-Quattro-II-5kVA-230VAC-24VDC-600-800Ah-Li-Lynx-Smart-BMS-distributors-Cerbo-generator-MPPT-Orion-Tr-Smarts.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Manual \u0026amp; Drawing Quattro-II 5kVA 230VAC 24VDC 600-800Ah Li Lynx Smart BMS distributors Cerbo generator MPPT Orion Tr Smarts\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Manual-%26-Drawing-Multi-RS-Solar-48-6000-Smart-LiFePO4-48V-200Ah-Lynx-Smart-BMS-Cerbo-GX-touch-70.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Manual \u0026amp; Drawing Multi RS Solar 48 6000 Smart LiFePO4 48V 200Ah Lynx Smart BMS Cerbo GX touch 70\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Manual-and-Drawing-Multi-RS-Solar-48-6000-DT-3Phase-Smart-LiFePO4-48V-600Ah-Lynx-Smart-BMS-Class-T-Power-In-Distributor-Ekrano-GX.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Manual and Drawing Multi RS Solar 48 6000 DT 3Phase Smart LiFePO4 48V 600Ah Lynx Smart BMS Class-T Power In Distributor Ekrano GX\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/MultiPlus-II-3kVA-120VAC-12VDC-2x300Ah-Li-NG-Lynx-Class-T-Smart-BMS-NG-Distributor-Cerbo-GX-touch-50-SBP-220-generator-MPPT-100-50-Orion-XS.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ MultiPlus-II 3kVA 120VAC 12VDC 2x300Ah Li-NG Lynx Class-T Smart BMS-NG Distributor Cerbo GX Touch-50 SBP-220 generator MPPT 100\/50 Orion XS\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/MultiPlus-3kVA-120VAC-12VDC-2x300Ah-Li-NG-Lynx-Class-T-Smart-BMS-NG-Distributor-Cerbo-GX-touch-50-SBP-220-generator-MPPT-100-50-Orion-Tr-smart.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ MultiPlus 3kVA 120VAC 12VDC 2x300Ah Li-NG Lynx Class-T Smart BMS-NG Distributor Cerbo GX touch-50 SBP-220 generator MPPT 100-50 Orion Tr smart\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/MultiPlus-3kVA-230VAC-12VDC-2x200Ah-Li-NG-Lynx-Class-T-Smart-BMS-NG-Distributor-Cerbo-GX-touch-50-SBP-220-generator-MPPT-100-50-Orion-XS.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ MultiPlus 3kVA 230VAC 12VDC 2x200Ah Li-NG Lynx Class-T Smart BMS-NG Distributor Cerbo GX touch-50 SBP-220 generator MPPT 100-50 Orion-XS\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/MultiPlus-3kVA-230VAC-12VDC-2x300Ah-Li-NG-Lynx-Class-T-Smart-BMS-NG-Distributor-Cerbo-GX-touch-50-SBP-220-generator-MPPT-100-50-extra-Alternator-WS500-Pro.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ MultiPlus 3kVA 230VAC 12VDC 2x300Ah Li-NG Lynx Class-T Smart BMS-NG Distributor Cerbo GX touch-50 SBP-220 generator MPPT 100-50 extra Alternator WS500-Pro\u003c\/a\u003e\n\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/Narrow-Boat-MultiPlus-3kVA-230VAC-12VDC-2x200Ah-Li-NG-Lynx-Class-T-Smart-BMS-NG-Distributor-Cerbo-GX-touch-50-SBP-220-MPPT-100-50-extra-Alternator-WS500-Pro-Bow-thruster-Galvanic-isolator-BMV-712.pdf\" target=\"_blank\" rel=\"noopener noreferrer\" style=\"display:inline-flex;align-items:center;gap:8px;padding:10px 14px;border:1px solid rgba(0,0,0,0.18);border-radius:10px;background:rgba(0,0,0,0.03);text-decoration:none;font-weight:600;line-height:1.1;\"\u003e⬇️ Narrow Boat MultiPlus 3kVA 230VAC 12VDC 2x200Ah Li-NG Lynx Class-T Smart BMS-NG Distributor Cerbo GX touch-50 SBP-220 MPPT 100-50 extra Alternator WS500-Pro Bow thruster Galvanic isolator BMV-712\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52617604432210,"sku":"LYN034160200","price":919.6,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1029\/7779\/8482\/files\/Lynx_20Smart_20BMS_201000_20_28M10_29.png?v=1770260243","url":"https:\/\/www.aquagridmarine.nl\/products\/lyn034160200","provider":"AquaGrid Marine","version":"1.0","type":"link"}