Lynx Smart BMS 1000 NG M10
The Lynx Smart BMS NG is an advanced battery management system specifically designed for Victron Energy Lithium NG batteries (not to be confused with the Lynx Smart BMS , which is for Victron Lithium Battery Smart batteries). This robust BMS ensures seamless performance, optimal safety, and efficient monitoring for Lithium NG battery banks, which are available with nominal voltages of 12.8 V, 25.6 V, and 51.2 V and various capacities. Available in two sizes—500 A and 1000 A—the Lynx Smart BMS NG offers a reliable, safe, and user-friendly solution.
The battery systems can be configured in series, parallel, or a combination of both, suitable for 12 V, 24 V, and 48 V systems. Each system can accommodate up to 50 batteries and provide up to 192 kWh (12 V) or 384 kWh (24 V/48 V) of energy storage. Multiple Lynx Smart BMS units connected in parallel can expand capacity and provide redundancy.
Key functions:
- Built-in 500 A or 1000 A contactor: Provides fail-safe operation and allows remote switching of the main system.
- Battery Monitoring: Displays charge status and other important data for efficient system management.
- Pre-alarm signal: Alarms before system shutdown due to low cell voltage
- Bluetooth connectivity: Easily set up, monitor and diagnose the system from our VictronConnect app.
- Local & Remote Monitoring: Compatible with Victron GX devices, such as the Cerbo GX , and the VRM Portal for real-time monitoring.
- M10 distribution rail integration: Connects seamlessly to all Lynx M10 products, ensuring smooth integration into the Lynx Distributor system .
The Lynx Smart BMS NG is an integral part of the modular Lynx Distribution system.
Specifications
| Feature | Value |
|---|---|
| allowChargeCurrentRating | 0.5A at 60VDC, protected by resettable fuse |
| allowDischargreCurrentRating1 | 0.5A at 60VDC, protected by resettable fuse |
| auxCurrentRating | 1.1 A continuous, protected by resettable fuse |
| batteryCommunicationTerminals | Terminals with M8 circular connectors |
| busbarConnections | M10 |
| busbarDimensions | 8mm x 30mm |
| busbarMaterial | Tinned copper |
| color | Blue (RAL 5012) |
| currentRating | 1,000 A |
| currentRatingpeak | 1,200 A |
| dataConnection | |
| depth | 100 mm |
| ems | EN-IEC 61000-6-3 |
| fuseConnections | |
| fuseDummy | |
| height | 230 mm |
| ioConnection | |
| lynxDistributorFuseMonitoring | RJ10 (RJ10 cables ship with each Lynx Distributor) |
| material | ABS |
| maxHumidity | 95% |
| maxInputVoltage | 75 V |
| operatingTempRange | |
| powerConnectionDistributor | |
| powerConsumption | |
| powerConsumptionOff | 0.3mA for all system voltages |
| powerConsumptionOn | Approximately 4.2W (350mA at 12V) depending on the state of the relays |
| powerConsumptionStandby | Approximately 0.6W (50mA at 12V) |
| prechargeLoadResistance | 10? and above for 12V systems 20? and above for 24V and 48V systems |
| programmableRelay | SPDT - 2 A at 60 VDC |
| protection Category | IP22 |
| qms | NEN-EN-ISO 9001 |
| relayConnection | |
| reversePolarityProtection | |
| safety | EN-IEC 63000 |
| storageTempRange | |
| systemVoltages | 12V or 24V or 48V |
| temperatureSensorConnection | |
| veCan | RJ45 |
| voltage range | [9, 60] V |
| weight | 2.7 kg |
| width | 180 mm |